کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
267854 504417 2012 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Applicability investigation of code-defined procedures on seismic performance assessment of typical school buildings in Taiwan
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات مهندسی ژئوتکنیک و زمین شناسی مهندسی
پیش نمایش صفحه اول مقاله
Applicability investigation of code-defined procedures on seismic performance assessment of typical school buildings in Taiwan
چکیده انگلیسی

Seismic resistance of elementary and high school buildings is of great concern due to high earthquake risk in Taiwan. Existing school buildings are often built of similar configurations, and designed based on previous building codes, which are not in compliance with current codes in seismic performance objective. The use of current code procedures on seismic performance assessment of existing typical school buildings may not be applicable in predicting their structural behavior during earthquakes. This paper describes a full-size two-story, three-bay frame structure test of typical school building design in Taiwan, and examines the performance and failure mechanism of the frame structure with current building codes. Results from loading test show good agreement with the code-defined procedures in identifying soft story, weak story, and failure modes of columns, but show different failure mechanism in beam–column joint region, i.e. strong-column–weak-beam is expected by building code procedures, whereas the test specimen exhibits weak-column–strong-beam behavior. Although the joint shear check following current code procedures gives satisfactory results, i.e. is consistent with the experiment, the check on its own is not a reasonable one. Revisions of current checking procedures for failure mechanism in beam column joint and for joint shear are also proposed in this paper for existing non-ductile reinforced concrete school buildings. The revised procedures incorporate the effects of both weak story and weak-column–strong-beam behavior. After adopting the proposed procedures, the predicted structural behavior and failure modes are consistent with those observed from the full-size frame test.


► A full-size two-story frame test of typical school building design is conducted.
► Results from the load test are compared with code-defined procedures.
► Revised code procedures are proposed for existing aged reinforced concrete school buildings.
► The revised procedures give consistent results with those observed from the load test.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Structures - Volume 36, March 2012, Pages 147–159
نویسندگان
, , , , ,