کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
271592 504998 2013 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Tritium retention to the first wall of JT-60U
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Tritium retention to the first wall of JT-60U
چکیده انگلیسی

For economic and safety reasons, tritium (T) accumulation on plasma facing wall (PFW) of fusion reactor is strictly limited. In this study, T inventory in the graphite tiles used at the first wall of JT-60U was measured by a full combustion method. It was found that T was only retained near plasma facing surfaces sides of the tiles and the amount of retained T increased from <1011 to <1013 T atoms/cm2 with increasing the exposed discharge period of the tiles. Integrating the T retention with the total surface area of the outer first wall tiles, the fraction of retained T in that area was estimated to be 13% of the total T production. It was confirmed that these retained T were part of the energetic T produced by DD reactions without being replaced by HH discharges. Based on the retained fraction, the annual amount of T retention in the outer first wall of a demo-size reactor was calculated to be 360 g/burn-year at maximum. Even the value would be much less in the reactor, the accumulation of this kind of inventory could have significant contribution to the total T inventory.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volume 88, Issue 5, June 2013, Pages 295–298
نویسندگان
, , , , , , , , , , ,