کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
296111 511708 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Conceptual design of a passive moderator cooling system for a pressure tube type natural circulation boiling water cooled reactor
ترجمه فارسی عنوان
طراحی مفهومی یک سیستم خنک کننده منفعل برای یک لوله فشار نوع رآکتور آب سرد در گردش آب طبیعی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
چکیده انگلیسی


• Passive moderator cooling system is designed to cool moderator passively during SBO.
• PMCS is a system of two natural circulation loops, coupled via a heat exchanger.
• RELAP5 analyses show that PMCS maintains moderator within safe limits for 7 days.

The recent Fukushima accident has raised strong concern and apprehensions about the safety of reactors in case of a prolonged Station Black Out (SBO) continuing for several days. In view of this, a detailed study was performed simulating this condition in Advanced Heavy Water Reactor. In this study, a novel concept of moderator cooling by passive means has been introduced in the reactor design. The Passive Moderator Cooling System (PMCS) consists of a shell and tube heat exchanger designed to remove 2 MW heat from the moderator inside Calandria. The heat exchanger is located at a suitable elevation from the Calandria of the reactor, such that the hot moderator rises due to buoyancy into the heat exchanger and upon cooling from shell side water returns to Calandria forming a natural circulation loop. The shell side of the heat exchanger is also a natural circulation loop connected to an overhead large water reservoir, namely the GDWP. The objective of the PMCS is to remove the heat from the moderator in case of an SBO and maintaining its temperature below the permissible safe limit (100 °C) for at least 7 days. The paper first describes the concept of the PMCS. The concept has been assessed considering a prolonged SBO for at least 7 days, through an integrated analysis performed using the code RELAP5/MOD3.2 considering all the major components of the reactor. The analysis shows that the PMCS is able to maintain the moderator temperature below boiling conditions for 7 days.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Engineering and Design - Volume 291, September 2015, Pages 261–270
نویسندگان
, , , ,