چکیده انگلیسی


• COD mineralization by peroxone studied in a direct potable water reuse system.
• Rate constant for OH oxidation of secondary effluent COD: (1.24 ± 0.64) × 107 M−1 S−1
• Pseudo-1st order rate constants vs. dose for design of peroxone COD mineralization.
• ORP and dissolved ozone as indicators of peroxone organics mineralization.
• Peroxone energy demand: 1.73–2.49 kW h/m3/log secondary effluent COD oxidation.

Mineralization of organics in secondary effluent by the peroxone process was studied at a direct potable water reuse research treatment system serving an occupied four-bedroom, four bath university residence hall apartment. Organic concentrations were measured as chemical oxygen demand (COD) and kinetic runs were monitored at varying O3/H2O2 dosages and ratios. COD degradation could be accurately described as the parallel pseudo-1st order decay of rapidly and slowly-oxidizable fractions, and effluent COD was reduced to below the detection limit (<0.7 mg/L). At dosages ≥4.6 mg L−1 h−1, an O3/H2O2 mass ratio of 3.4–3.8, and initial COD <20 mg/L, a simple first order decay was indicated for both single-passed treated wastewater and recycled mineral water, and a relationship is proposed and demonstrated to estimate the pseudo-first order rate constant for design purposes. At this O3/H2O2 mass ratio, ORP and dissolved ozone were found to be useful process control indicators for monitoring COD mineralization in secondary effluent. Moreover, an average second order rate constant for OH oxidation of secondary effluent organics (measured as MCOD) was found to be 1.24 × 107 ± 0.64 × 107 M−1 S−1. The electric energy demand of the peroxone process is estimated at 1.73–2.49 kW h electric energy for removal of one log COD in 1 m3 secondary effluent, comparable to the energy required for desalination of medium strength seawater. Advantages/disadvantages of the two processes for municipal wastewater reuse are discussed.