کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4916668 | 1428103 | 2017 | 14 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Residential heat pump as flexible load for direct control service with parametrized duration and rebound effect
ترجمه فارسی عنوان
پمپ حرارتی مسکونی به عنوان بار انعطاف پذیر برای خدمات کنترل مستقیم با مدت زمان پارامتری و اثر بازپرداخت
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
پمپ های حرارتی، برنامه ریزی خطی، مدیریت بار، مدل سازی بار، روش های بهینه سازی، سیستم های قدرت،
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
مهندسی انرژی و فناوری های برق
چکیده انگلیسی
This paper addresses the problem of an aggregator controlling residential heat pumps to offer a direct control flexibility service. The service consists of a power modulation, upward or downward, that is activated at a given time period over a fixed number of periods. The service modulation is relative to an optimized baseline that minimizes the energy costs. The load modulation is directly followed by a constrained rebound effect, consisting of a delay time with no deviations from the baseline consumption and a payback time to return to the baseline state. The potential amount of modulation and the constrained rebound effect are computed by solving mixed integer linear problems. Within these problems, the thermal behavior of the building is modeled by an equivalent thermal network made of resistances and lumped capacitances. Simulations are performed for different sets of buildings typical of the Belgian residential building stock and are presented in terms of achievable modulation amplitude, deviations from the baseline and associated costs. A cluster of one hundred ideal buildings, corresponding to retrofitted freestanding houses, is then chosen to investigate the influence of each parameter defined within the service. Results show that with a set of one hundred heat pumps, a load aggregator could expect to harvest mean modulation amplitudes of up to 138Â kW for an upward modulation and up to 51Â kW for a downward modulation. The obtained values strongly depend on the proposed flexibility service. For example, they can decrease down to 2.6Â kW and 0.4Â kW, respectively, if no rebound effect is allowed.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 187, 1 February 2017, Pages 140-153
Journal: Applied Energy - Volume 187, 1 February 2017, Pages 140-153
نویسندگان
Emeline Georges, Bertrand Cornélusse, Damien Ernst, Vincent Lemort, Sébastien Mathieu,