کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5008709 1462037 2018 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ultrasensitive electrochemiluminescence immunosensor for determination of hepatitis B virus surface antigen using CdTe@CdS-PAMAM dendrimer as luminescent labels and Fe3O4 nanoparticles as magnetic beads
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Ultrasensitive electrochemiluminescence immunosensor for determination of hepatitis B virus surface antigen using CdTe@CdS-PAMAM dendrimer as luminescent labels and Fe3O4 nanoparticles as magnetic beads
چکیده انگلیسی


- An ECLimmunosensor designed for detection of hepatitis B virus surface antigen(HBsAg).
- The primary antibody of HBs (Ab1) was immobilized on magnetic nanoparticles (MNPs) .
- Secondary antibody (Ab2)/dendrimer/CdTe@CdS QDs used for complete sandwich assay.
- Synergetic effects of MNPs/dendrimer improved DL of the immunosensor to 0.8 fg/ml.
- Sensor liner range was up to 0.3 ng/ml and it applied to HBsAg analysis in human serum.

Here, a sandwich-type electrochemiluminescence (ECL) immunosensor for ultrasensitive determination of HBsAg was designed based on signal amplification with dendrimeric-quantum dots structures. First, the primary antibody of HBs (Ab1) was immobilized on the surface of the carboxyl-modified magnetic nanoparticles (MNPs). Then, the PAMAM dendrimer with many amine functional groups was employed as the carrier for immobilizing CdTe@CdS quantum dots (QDs) and the secondary antibody (Ab2) which can amplify the ECL signal of QDs significantly and improve the sensitivity of the proposed method. Dendrimer increasing loading of CdTe@CdS-Ab2 labels, while ECL response from CdTe@CdS QDs enhanced 4 folds compared to the unamplified protocol. Furthermore, MNPs enhances the electron transfer between the nanoprobe and the electrode and also, their large surface area leads to immobilize more Ab1. Under the optimal conditions, the constructed immunosensor showed a wide linear range from 3 fg mL−1 to 0.3 ng mL−1 with the detection limit of 0.80 fg mL−1 (S/N ratio of 3) for HBsAg detection. The proposed ECL immunosensor exhibited good analytical performance and excellent stability and it was applied for HBsAg detection in human serum samples with satisfactory results.

145

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 254, January 2018, Pages 551-560
نویسندگان
, , ,