کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5016906 1466054 2017 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Full-range stress intensity factor solutions for clamped SENT specimens
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی مکانیک
پیش نمایش صفحه اول مقاله
Full-range stress intensity factor solutions for clamped SENT specimens
چکیده انگلیسی


- The stress intensity factor K solutions were reinvestigated for clamped SENT specimens.
- A general, full-range analytical solution of K was obtained for H/W≥3 with accuracy of 0.25%.
- The corrected K solution obtained previously for BS 8571 was shown accurate for crack sizes of a/W≤0.925.
- The actual valid ranges of three FEA results of K were redefined.
- A simple closed-form solution of K was proposed for clamped SENT specimens with H/W = 10.

Single edge notched tension (SENT) specimen with clamped ends has been receiving increasing attention worldwide as a low-constraint specimen to measure less-conservative fracture toughness of pipeline steels in the oil and gas industry. Several SENT test methods were developed, but the solutions of stress intensity factor K used are different. The existing K solutions are thus reviewed and evaluated in this paper for the clamped SENT specimens, and then a full-range analytical solution of K is developed as a function of full-range crack sizes (a/W) and specimen aspect ratios (H/W). From this result, a simple closed-form solution of K is obtained particularly for H/W = 10, as used by the current SENT toughness test methods. The proposed full-range K solutions are validated using different numerical results and error analyses, and thus can be used generally to meet the needs of different SENT testing for determination of fatigue crack growth rate or fracture toughness in the low-constraint conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Pressure Vessels and Piping - Volume 149, January 2017, Pages 1-13
نویسندگان
,