کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5030363 1470669 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Solution of Leakage Problem in a Guarded Hot Plate Device
ترجمه فارسی عنوان
راه حل مشکل نشت در یک دستگاه پلیت گرم محافظ
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی (عمومی)
چکیده انگلیسی

The conduction heat transfer coefficients of the fibrous insulation materials depend on temperature, especially under high temperature conditions. In this study, the device, called guarded hot plate (GHP), measuring the heat transfer performance of insulation materials under high temperature conditions is improved. Circulation of the cooling fluid inside aluminum cold plates is optimized by numerical results. To prevent leakage of the fluid, metal pipes are inserted into the conduits aiming the fluid to circulate throughout these pipes. Following the design, the cold plates are manufactured and the computational results are validated by the experimental ones. By the new designed cold plate, the system operates and achieves validated measurements for the thermal conductivity of the fibrous insulation materials, under high temperature conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Procedia Engineering - Volume 157, 2016, Pages 488-495
نویسندگان
, , ,