کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
504875 864447 2015 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of the effect of different sampling modes on computer analysis of cardiotocograms
ترجمه فارسی عنوان
مقایسه اثر روش های مختلف نمونه گیری بر روی تجزیه و تحلیل کامپیوتری cardiotocograms
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر نرم افزارهای علوم کامپیوتر
چکیده انگلیسی


• FHR sampling mode affects usual computer analysis of CTGs.
• Effect of FHR sampling mode on computer analysis depends on parameters definition.
• Alerts in computer analysis of CTGs should take into account the FHR sampling mode.

BackgroundCardiotocographic (CTG) monitors may provide fetal heart rate (FHR) signals as beat-to-beat (BTB) or alternatively at a fixed sampling rate. The aim of this study was to assess the effect of different sampling modes on the evaluation provided by a commercially available system for computer analysis of CTGs.MethodsInternal FHR signals were acquired during the last hour of labor in 27 singleton term cephalic pregnancies, using the STAN S31® fetal monitor (Neoventa, Gothemburg, Sweden). BTB and 4 Hz sampling outputs of the monitor were compared using the Omniview-SisPorto® system for computer analysis of CTGs (Speculum, Lisbon, Portugal). The following parameters were analyzed: signal loss, signal quality, baseline, accelerations, decelerations, percentage of abnormal short-term variability (%aSTV), abnormal long-term variability (%aLTV), average short-term variability (avSTV) and the system׳s clinical alerts. Statistical inference was performed using the Spearman correlation coefficient, 95% nonparametric confidence intervals, Wilcoxon and McNemar statistical tests, setting significance at 0.05, and a non-parametric measure of disagreement (valued 0–1 from lowest to highest disagreement).ResultsComparing BTB with 4 Hz sampling, the median values for signal quality (95% versus 96%), number of accelerations (5 versus 7) and %aSTV (31 versus 39) were significantly lower in the former. On the other hand, with BTB signals the median value of avSTV was significantly higher (3.1 versus 2.3). Nevertheless, BTB and 4 Hz parameters were highly correlated (r=0.89–0.97), and there were no significant differences in the quantification of the number of decelerations or in the clinical alerts elicited by the system.ConclusionsIn conclusion, different sampling modes have a significant effect on the parameters provided by computer analysis of CTGs that are related with the quantification of STV, with a small impact on baseline estimation and on the subsequent quantification of accelerations. However, there does not seem to be significant impact on the quantification of decelerations or on the alerts provided by the system.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Computers in Biology and Medicine - Volume 64, 1 September 2015, Pages 62–66
نویسندگان
, , , , ,