Median prior constrained TV algorithm for sparse view low-dose CT reconstruction
ترجمه فارسی عنوان
الگوریتم TV محدود Median prior برای بازسازی CT با دوز کم مشاهده پراکنده
کلمات کلیدی
CT با دوز کم؛ تنوع کامل؛ مشاهده پراکنده ؛ Median prior؛ بازسازی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر نرم افزارهای علوم کامپیوتر
چکیده انگلیسی


• A Median prior constrained TV algorithm is proposed for sparse view low-dose CT reconstruction.
• The median gradient proves to be sparse as well gradient image.
• The proposed algorithm can not only ensure a higher SNR but also a higher resolution.

It is known that lowering the X-ray tube current (mAs) or tube voltage (kVp) and simultaneously reducing the total number of X-ray views (sparse view) is an effective means to achieve low-dose in computed tomography (CT) scan. However, the associated image quality by the conventional filtered back-projection (FBP) usually degrades due to the excessive quantum noise. Although sparse-view CT reconstruction algorithm via total variation (TV), in the scanning protocol of reducing X-ray tube current, has been demonstrated to be able to result in significant radiation dose reduction while maintain image quality, noticeable patchy artifacts still exist in reconstructed images. In this study, to address the problem of patchy artifacts, we proposed a median prior constrained TV regularization to retain the image quality by introducing an auxiliary vector m in register with the object. Specifically, the approximate action of m is to draw, in each iteration, an object voxel toward its own local median, aiming to improve low-dose image quality with sparse-view projection measurements. Subsequently, an alternating optimization algorithm is adopted to optimize the associative objective function. We refer to the median prior constrained TV regularization as “TV_MP” for simplicity. Experimental results on digital phantoms and clinical phantom demonstrated that the proposed TV_MP with appropriate control parameters can not only ensure a higher signal to noise ratio (SNR) of the reconstructed image, but also its resolution compared with the original TV method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Computers in Biology and Medicine - Volume 60, 1 May 2015, Pages 117–131
نویسندگان
, , , , , ,