کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5130586 1490842 2017 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Hydrogels of polyaniline with graphene oxide for highly sensitive electrochemical determination of lead ions
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Hydrogels of polyaniline with graphene oxide for highly sensitive electrochemical determination of lead ions
چکیده انگلیسی


- A novel polyaniline-graphene oxide hydrogel was explored for lead ions sensor..
- The detection limit obtained for this electrode is 0.04 nM with the longer linear concentration range.
- The electrode also showed an average of ∼99.4% removal of Pb2+ ions with a relative standard deviation of 3.4%.
- The developed platform was successfully used for the analysis of real water samples.

Conducting polymers with graphene/graphene oxide hydrogels represent a unique class of electrode materials for sensors and energy storage applications. In this article, we report a facile in situ method for the polymerisation of aniline resulting in the decoration of 1D conducting polyaniline (PANI) nanofibers onto the surface of 2D graphene oxide (GO) nanosheets followed by hydrogel formation at elevated temperature. The synthesized nanomaterial exhibits significant properties for the highly sensitive electrochemical determination as well as removal of environmentally harmful lead (Pb2+) ions. The square wave anodic stripping voltammetry (SWASV) determination of Pb2+ ions showed good electroanalytical performance with two linear ranges in 0.2-250 nM (correlation coefficient = 0.996) and 250-3500 nM (correlation coefficient = 0.998). The developed protocol has shown a limit of detection (LOD) of about 0.04 nM, which is much lower than that of the World Health Organization (WHO) threshold limits. The prepared electrode showed an average of ∼99.4% removal of Pb2+ ions with a relative standard deviation (RSD) of 3.4%. Selectivity of the electrode towards Pb2+ ions were tested in presence of potential interferences such as Na+, K+, Ca2+, Mg2+, Cu2+, Cd2+, Hg2+, Zn2+, Co2+, Ni2+, Fe2+ and Fe3+ of similar and higher concentrations. The sensor showed good repeatability and reproducibility. The developed protocol was used to analyse samples from industrial effluents and natural water samples. The results obtained were correlated with atomic absorption spectroscopy (AAS).

281

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 990, 16 October 2017, Pages 67-77
نویسندگان
, , , , , ,