کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5135236 1493428 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Preparation of organic-silica hybrid monolithic columns via crosslinking of functionalized mesoporous carbon nanoparticles for capillary liquid chromatography
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Preparation of organic-silica hybrid monolithic columns via crosslinking of functionalized mesoporous carbon nanoparticles for capillary liquid chromatography
چکیده انگلیسی


- MCNs are incorporated into butyl-silica hybrid monoliths as cross-linkers.
- The crosslinking of MCNs increases specific surface area of the hybrid monolith.
- The crosslinking of MCNs enhances the RP retention for separation of small molecules.
- The MCN-incorporated butyl-silica monolith demonstrates high separation efficiency.
- The analysis of peptides from BSA digest indicates its great potential in proteomics.

An organic-silica hybrid monolithic capillary column was fabricated by crosslinking (3-aminopropyl)trimethoxysilane (APTMS) modified mesoporous carbon nanoparticles (AP-MCNs) with tetramethoxysilane (TMOS) and n-butyltrimethoxysilane (C4-TriMOS). Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy, mercury intrusion porosimetry and inverse size-exclusion chromatography characterization proved the successful immobilization of mesoporous carbon nanoparticles (MCNs). The crosslinking of AP-MCNs into the hybrid monolithic matrix has significantly increased the reversed-phase retention of alkylbenzenes and chromatographic performance for small molecules separations in comparison with the neat one without MCNs. The resulting column efficiency of the mesoporous carbon nanoparticle-based butyl-silica hybrid monolithic column (MCN-C4-monolith) was up to ca. 116,600 N/m for the capillary liquid chromatography (cLC) separation of butylbenzene. Enhanced performance of proteins separation was achieved on the MCN-C4-monolith in comparison with the butyl-silica hybrid monolithic column without MCN (C4-monolith). The separation of peptides from bovine serum albumin (BSA) digest was carried out on the MCN-C4-monolith by capillary liquid chromatography-tandem mass spectrometry (cLC-MS/MS) with protein sequence coverage of 81.9%, suggesting its potential application in proteomics.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1498, 19 May 2017, Pages 64-71
نویسندگان
, , , , , , , ,