کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5483765 1522532 2017 20 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of Hg occurrence in coal on accuracy of Hg direct measurement based on thermal decomposition
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات زمین شناسی اقتصادی
پیش نمایش صفحه اول مقاله
Influence of Hg occurrence in coal on accuracy of Hg direct measurement based on thermal decomposition
چکیده انگلیسی
To better monitor and control Hg emissions from coal-fired power plants, quantification of Hg contents in coal is essential. Thermal decomposition is widely used to pretreat solid samples. The complete thermal release of Hg in coal samples is a premise for obtaining accurate results of measured Hg contents. The recommended heating temperature is 800 °C for coal samples. The research work in this paper has verified the existence of an abnormal phenomenon, where some Hg occurrences in typical coal at 800 °C could not fully decompose. The temperature-programmed pyrolysis was designed to validate the assumption and determine the optimum decomposition temperature. The results demonstrate that Hg combined with montmorillonite mineral fully decomposes at temperatures above 800 °C. The obtained results help to clarify the relationship between the decomposition temperature and Hg occurrence. The study offers good guidance to improve the accuracy of measured Hg contents by thermal decomposition, thus expanding the laboratory and industrial application.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Coal Geology - Volume 170, 1 February 2017, Pages 14-18
نویسندگان
, , , , , ,