کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5498540 1533361 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Original paperPhotoneutron depth dose equivalent distributions in high-energy X-ray medical accelerators by a novel position-sensitive dosimeter
ترجمه فارسی عنوان
مقیاس اصلی توزیع مقادیر معادل اکسیژن فتوتونوترون در شتاب دهنده های پزشکی اشعه ایکس با انرژی بالا توسط یک حسگر جدید حساس
کلمات کلیدی
اشعه ماوراء بنفش بالا، فوتونیترون، عمق دوز معادل، دیزیمتر پلی کربنات، حساس به موقعیت رادیوتراپی،
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
چکیده انگلیسی


- Photoneutron (PN) depth, profile and isodose equivalent distributions were determined.
- Novel mega-size position-sensitive polycarbonate dosimeters were applied.
- Dose distributions on transverse, longitudinal and diagonal axes were determined.
- Extensive PN dose equivalent matrix data at 8 depths in a phantom are reported.
- The dosimetry method can determine PN dose equivalent at any position at depth.

PurposeThe purpose of this study was to; (1) investigate employing a novel position-sensitive mega-size polycarbonate (MSPC) dosimeter for photoneutron (PN) depth, profile and dose equivalent distributions studies in a multilayer polyethylene phantom in a Siemens ONCOR accelerator, and (2) develop depth dose equivalent distribution matrix data at different depths and positions of the phantom for patient PN dose equivalent determination and in particular for PN secondary cancer risk estimation.MethodsPosition-sensitive MSPC dosimeters were successfully exposed at 9 different depths of the phantom in a 10 × 10 cm2 X-ray field. The dosimeters were processed in mega-size electrochemical chambers at optimum conditions. Each MSPC dosimeter was placed at a known phantom depth for PN depth dose equivalents and profiles on transverse, longitudinal and diagonal axes and isodose equivalent distribution studies in and out of the X-ray beam.ResultsPN dose equivalent distributions at any depth showed the highest value at the beam central axis and decreases as the distance increases. PN dose equivalent at any position studied in the axes has a maximum value on the phantom surface which decreases as depth increases due to flux reduction by multi-elastic scattering interactions.ConclusionsExtensive PN dose equivalent matrix data at different depths and positions in the phantom were determined. The position-sensitive MSPC dosimeters proved to be highly efficient for PN depth, profile and isodose equivalent distribution studies. The extensive data obtained highly assists for determining PN dose equivalent of a patient undergoing high-energy X-ray therapy and for PN secondary cancer risk estimation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physica Medica - Volume 36, April 2017, Pages 73-80
نویسندگان
, ,