کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5521947 1545659 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Research paperMonitoring native HLA-I trimer specific antibodies in Luminex multiplex single antigen bead assay: Evaluation of beadsets from different manufacturers
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی بیوتکنولوژی یا زیست‌فناوری
پیش نمایش صفحه اول مقاله
Research paperMonitoring native HLA-I trimer specific antibodies in Luminex multiplex single antigen bead assay: Evaluation of beadsets from different manufacturers
چکیده انگلیسی


- Luminex HLA-I beads may carry several HLA-variants in addition to native trimeric HLAI.
- Epitope specific monoclonal antibodies distinguished the variants on diverse beadsets.
- Beadset A and Beadset B had three and two structural HLA-variants, respectively.
- Beadset C had only the native trimeric HLA-I and specifically detect anti-HLA-I trimer.

Luminex single antigen bead (SAB) assay utilizes beadsets coated with a set of cloned and purified HLA molecules, for monitoring serum anti-HLA antibodies. Particularly, the level of serum IgG against native HLA-I trimers (heavy chain (HC) and β2-microglobulin (β2 m) with a peptide), expressed in allograft tissues is correlated with graft failure. In addition to native trimeric HLAI, the beadsets may carry HC only or the dimeric variants, peptide-free HC with β2 m and β2 m-free HC with or without peptides. Currently, three different HLA-I coated beadsets have been produced commercially. The HLA antigen density on one beadset was reported to be approximately 50% of that present on another beadset as evidenced by the binding of an anti-HLA-I mAb W6/32. To date, no efforts have been made to compare the relative distribution of HLA-I variants in these three beadsets. In this study, using monoclonal antibodies (W6/32, HC-10 and TFL-006) that can distinguish the structural variants based on their epitope specificities, the nature of the variants in the three beadsets were comparatively evaluated. One beadset (Beadset A, see Materials and methods for Brand and Manufacturer's names) (W6/32 +/HC-10 +/TFL-006 +) carried at least three variants, while beadset B (W6/32 +/HC-10 +/TFL-006-) carried two (peptide-associated and peptide-free β2 m-HC) and the beadset C (W6/32 +/HC-10 −/TFL-006-) carried exclusively the HLA-I trimer suggesting its usefulness for specific monitoring native HLA-I trimer antibodies. Because of the salient differences in the variants coated on the different beadsets, it would be warranted to investigate, if these differences are clinically relevant for monitoring serum anti-HLA antibodies in sensitized patients waiting for donor organs and in allograft recipients (274).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Immunological Methods - Volume 450, November 2017, Pages 73-80
نویسندگان
, , ,