کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5631278 1580862 2017 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The effect of acquisition resolution on orientation decoding from V1 BOLD fMRI at 7 T
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب شناختی
پیش نمایش صفحه اول مقاله
The effect of acquisition resolution on orientation decoding from V1 BOLD fMRI at 7 T
چکیده انگلیسی


- Best decoding performance at 2.0 mm acquisition resolution (four tested resolutions: 0.8, 1.4, 2.0, and 3.0 mm isotropic).
- Recording high-resolution data with subsequent spatial downsampling does not improve decoding performance.
- Most informative spatial frequency band covers ∼4.5 mm to 1.6 cm wavelength.
- Veins carry orientation specific signals, and contribute to decoding; potential source of complex spatial signal aliasing.

A decade after it was shown that the orientation of visual grating stimuli can be decoded from human visual cortex activity by means of multivariate pattern classification of BOLD fMRI data, numerous studies have investigated which aspects of neuronal activity are reflected in BOLD response patterns and are accessible for decoding. However, it remains inconclusive what the effect of acquisition resolution on BOLD fMRI decoding analyses is. The present study is the first to provide empirical ultra high-field fMRI data recorded at four spatial resolutions (0.8 mm, 1.4 mm, 2 mm, and 3 mm isotropic voxel size) on this topic - in order to test hypotheses on the strength and spatial scale of orientation discriminating signals. We present detailed analysis, in line with predictions from previous simulation studies, about how the performance of orientation decoding varies with different acquisition resolutions. Moreover, we also examine different spatial filtering procedures and its effects on orientation decoding. Here we show that higher-resolution scans with subsequent down-sampling or low-pass filtering yield no benefit over scans natively recorded in the corresponding lower resolution regarding decoding accuracy. The orientation-related signal in the BOLD fMRI data is spatially broadband in nature, includes both high spatial frequency components, as well as large-scale biases previously proposed in the literature. Moreover, we found above chance-level contribution from large draining veins to orientation decoding. Acquired raw data were publicly released to facilitate further investigation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage - Volume 148, 1 March 2017, Pages 64-76
نویسندگان
, , , , ,