کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5668086 1592333 2017 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of genomic drift of influenza PCR tests
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی میکروبیولوژی و بیوتکنولوژی کاربردی
پیش نمایش صفحه اول مقاله
Effect of genomic drift of influenza PCR tests
چکیده انگلیسی


- Some commercial PCR assays demonstrated difficulty with detecting the predominant influenza strains circulating in the USA in during the 2014-2015 season.
- Limit of detection analysis demonstrated that assay performance was strain associated.
- False negative influenza results were both a function of strain type and viral titer.
- Nucleotide sequence analysis demonstrated mutations which may be associated with assay performance.

BackgroundNucleic acid amplification assays have become the method of choice for influenza (Flu) testing due to superior accuracy and faster turnaround time. Although assays are designed to detect highly conserved genomic targets, mutations can influence test sensitivity. Most of the circulating viruses in the United States during the 2014-2015 season were associated with significant genetic drift; however, the effect on testing was unknown.Objectives and study designWe compared the performance of Prodesse ProFlu+/ProFAST+ (PFlu/PFAST), FilmArray Respiratory Panel (RP), cobas® Influenza A/B test (cIAB), and Xpert® Flu (Xpt) in a retrospective analysis of consecutive nasopharyngeal specimens received for a two-week period during the winter of 2015. Furthermore, limits of detection (LOD) were determined with six isolates of Flu.ResultsOf the 275 specimens, 63 were positive for FluA by PFAST, 60 were positive by RP, 58 were positive by cIAB and 52 were positive by Xpt. Only a subset of 135 specimens was tested by PFlu, of which 32 were positive. The sensitivity/specificity for PFAST, RP, cIAB, Xpt and PFlu was 100/99.1%, 96.7/99.5%, 91.8/99.1%, 85.2%/100%, and 75.6%/98.9%, respectively. LOD analyses demonstrated assay performance variations were strain associated. Specifically, PFlu's and cIAB's LODs were higher with A/Texas/50/2012-like and A/Switzerland/9715293/2013-like strains, while Xpt's highest LOD was with the Swiss strain.ConclusionsStrain-associated assay performance variation is known to occur with other Flu test methods; hence, it is not surprising that such variation would be observed with molecular tests. Careful monitoring and reporting for strain-associated variances are warranted for all test methods.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Clinical Virology - Volume 93, August 2017, Pages 25-29
نویسندگان
, , , , , , , , ,