کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6025023 1580890 2015 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Reproducibility of multiphase pseudo-continuous arterial spin labeling and the effect of post-processing analysis methods
ترجمه فارسی عنوان
بازتوزیع برچسب زدن اسپین شبه مستمر چند مرحله و اثر روش های تجزیه و تحلیل پس از پردازش
کلمات کلیدی
مارپیچ اسپین برچسب زدن اسپین شریانی پیوسته پیوندی مستمر چندگانه، مغز استخوان جریان خون مغزی، تست مجدد، تکرارپذیری،
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب شناختی
چکیده انگلیسی


- The reproducibility of multiphase (MP) pseudo-continuous ASL (PCASL) is characterized.
- We propose an image processing pipeline for improving ASL reproducibility.
- MP-PCASL is shown to have higher signal-to-noise ratio and reproducibility than PCASL.
- The proposed pipeline can improve the reliability and sensitivity of ASL.
- An effective image post-processing should promote ASL in clinical applications.

Arterial spin labeling (ASL) is an emerging MRI technique for non-invasive measurement of cerebral blood flow (CBF). Compared to invasive perfusion imaging modalities, ASL suffers from low sensitivity due to poor signal-to-noise ratio (SNR), susceptibility to motion artifacts and low spatial resolution, all of which limit its reliability. In this work, the effects of various state of the art image processing techniques for addressing these ASL limitations are investigated. A processing pipeline consisting of motion correction, ASL motion correction imprecision removal, temporal and spatial filtering, partial volume effect correction, and CBF quantification was developed and assessed. To further improve the SNR for pseudo-continuous ASL (PCASL) by accounting for errors in tagging efficiency, the data from multiphase (MP) acquisitions were analyzed using a novel weighted-averaging scheme. The performances of each step in terms of SNR and reproducibility were evaluated using test-retest ASL data acquired from 12 young healthy subjects. The proposed processing pipeline was shown to improve the within-subject coefficient of variation and regional reproducibility by 17% and 16%, respectively, compared to CBF maps computed following motion correction but without the other processing steps. The CBF measurements of MP-PCASL compared to PCASL had on average 23% and 10% higher SNR and reproducibility, respectively.

61

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage - Volume 117, 15 August 2015, Pages 191-201
نویسندگان
, , , , , , ,