کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
607881 1454597 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Probing hysteresis during sorption of cyclohexane within mesoporous silica using NMR cryoporometry and relaxometry
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی شیمی کلوئیدی و سطحی
پیش نمایش صفحه اول مقاله
Probing hysteresis during sorption of cyclohexane within mesoporous silica using NMR cryoporometry and relaxometry
چکیده انگلیسی

The conventional data analysis methods for obtaining a pore size distribution (PSD) from gas sorption data make several critical assumptions that impact significantly on the accuracy of the PSD thereby obtained. In particular, assumptions must be made concerning the nature of the pore-filling or emptying process in adsorption, or desorption, respectively. The possibility of pore–pore interactions is also generally neglected. In this work, NMR cryoporometry and relaxometry have been used to study the adsorption and desorption of cyclohexane within a mesoporous, sol–gel silica catalyst support pellet with the aim of assessing the impact of the aforementioned problems for gas sorption PSDs and developing solutions. The advanced melting effect makes cryoporometry a particularly sensitive probe of adsorbate ganglia spatial distribution. It has been demonstrated that utilising gas sorption scanning curves provided insufficient additional information to alleviate the aforementioned problems with interpreting gas sorption data. The NMR data has shown how the nature of the sorption hysteresis changed with amount adsorbed, due to detectable variations in the mechanisms of pore-filling and emptying along the isotherm. Hence, relating a particular condensation or evaporation pressure to a specific characteristic pore size is not as straightforward as assumed in typical pore size analysis software. However, the NMR techniques reveal the additional information required to improve pore size estimates from gas sorption for disordered solids.

Figure optionsDownload high-quality image (57 K)Download as PowerPoint slideHighlights
► Demonstrates efficacy of cryoporometry advanced melting effect for studying advanced adsorption.
► Method to monitor variations in causes of hysteresis along the isotherm.
► Provides assessment of accuracy of conventional gas sorption PSDs.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Colloid and Interface Science - Volume 398, 15 May 2013, Pages 168–175
نویسندگان
, , , ,