- SECM was used to study current oscillations in the FeâH2SO4 system.
- A polyaniline-modified microelectrode was used to monitor pH at the interface.
- A Pt microelectrode was used to monitor Fe2Â + at the interface.
- pH oscillations were observed at the interface during the current oscillations.
- The oxide film plays a key role in the oscillations of the system.
An unmodified Pt microelectrode and a Pt microelectrode coated with polyaniline were used in conjunction with a scanning electrochemical microscope (SECM) to study anodic dissolution in the FeâH2SO4 system. The concentrations of Fe2Â + (cFe2Â +) measured with the unmodified microelectrode and the pH values measured with the polyaniline-modified microelectrode were recorded in situ during current oscillations in the FeâH2SO4 system and were found to change periodically at the FeâH2SO4 interface. The changes in cFe2Â + may be caused by the periodic formation and dissolution of surface film(s), which could be salt films and/or oxide films. If a salt film is formed, it is unlikely to affect the pH. Since the pH changes periodically during the current oscillations, it can be deduced that the surface film is mainly composed of oxide, and that the formation and dissolution of the oxide film play a key role in the current oscillations of the system.
Journal: Electrochemistry Communications - Volume 82, September 2017, Pages 103-106