Investigating corrosion memory: The influence of previous boiler operation on current corrosion rate
ترجمه فارسی عنوان
بررسی حافظه خوردگی: تأثیر عملیات قبلی دیگ بخار بر میزان خوردگی فعلی
کلمات کلیدی
حافظه خوردگی زیست توده، هدر، کیفیت سوخت،
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
چکیده انگلیسی


- A novel set up with exposures in two different boilers have been conducted to study dynamic corrosion mechanisms in a unique way.
- A positive corrosion memory effect of a non-corrosive deposit despite the problems with spallation could be observed.
- The corrosive deposit formed after the exposure in the highly corrosive environment did not show any effect when exposed again in a moderately corrosive environment.

The selection of fuel is crucial for a Combined Heat and Power (CHP) plant in terms of cost and corrosion and the fuel will vary over time. The corrosiveness of different fuels has been studied extensively, however, not how a current corrosion attack is influenced by corrosion history (i.e. previous deposit buildup and oxide scale formation) instead of the influence of the current flue gas composition (i.e. the current fuel mix being used). This influence of the corrosion history effect can be called “corrosion memory”.To investigate the corrosion memory effect on boilers, a novel setup was used. Air-cooled probe AISI304L samples were exposed in two different boilers to mimic different fuels. One boiler was a biomass-fired boiler representing a moderate corrosive fuel and the other was a waste-fired boiler representing a highly corrosive fuel. A three-step exposure program was performed in which a reference probe was exposed in the biomass-fired boiler for all three steps while another probe was exposed in the biomass-fired boiler for steps 1 + 3 and in the waste-fired boiler for the second step. All samples were investigated with material-loss measurements and SEM/EDX. The findings show that the deposit and oxide scales formed on the samples in the biomass-fired boiler had a mitigating effect on the corrosion attack. Consequently, corrosion history affects the future corrosion rate.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fuel Processing Technology - Volume 156, February 2017, Pages 348-356
نویسندگان
, , , , ,