The experimental friction factor and Nusselt number data for laminar flow through a circular duct having integral transverse ribs and fitted with centre-cleared twisted-tape have been presented. Predictive friction factor and Nusselt number correlations have also been presented. The thermohydraulic performance has been evaluated. The major findings of this experimental investigation are that the centre-cleared twisted tapes in combination with transverse ribs perform significantly better than the individual enhancement technique acting alone for laminar flow through a circular duct up to a certain amount of centre-clearance. This result is useful for the design of solar thermal heaters and heat exchangers.
► Laminar flow in transverse ribbed channel with centre-cleared twisted-tape is studied.
► Friction factor and Nusselt number correlations are developed.
► The thermohydraulic performance is evaluated.
► This finned geometry performs significantly better within limits.
► Results are useful for solar thermal heating and heat exchangers.
Journal: Experimental Thermal and Fluid Science - Volume 44, January 2013, Pages 727–735