کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
662906 1458151 2008 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of wall proximity in fluid flow and heat transfer from a rectangular prism placed inside a wind tunnel
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Effect of wall proximity in fluid flow and heat transfer from a rectangular prism placed inside a wind tunnel
چکیده انگلیسی

Experimental investigations in fluid flow and heat transfer have been carried out to study the effect of wall proximity due to flow separation around rectangular prisms. Experiments have been carried out for the Reynolds number 4.9 × 104, blockage ratios are 0.1, 0.2, 0.3 and 0.4, aspect ratio (d/c)(d/c) are 1.5, 1.33, 0.667 and 0.333, different height-ratios and various angles of attack. The static pressure distribution has been measured on all faces of the rectangular prisms. The results have been presented in the form of pressure coefficient, drag coefficient for various height-ratios and blockage ratios. The pressure distribution shows positive values on the front face whereas on the rear face negative values of the pressure coefficient have been observed. The positive pressure coefficient for different height-ratios does not vary too much but the negative values of pressure coefficient are higher for all points on the surface as the bluff body approaches the upper wall of the wind tunnel. The drag coefficient decreases with the increase in angle of attack as the height-ratio decreases. There is no definite angle of attack for all blockage ratios and Reynolds numbers at which the value of drag coefficient is either maximum or minimum. The heat transfer experiments have been carried out under constant heat flux condition. Heat transfer coefficient are determined from the measured wall temperature and ambient temperature and presented in the form of Nusselt number. Both local and average Nusselt numbers have been presented for various height-ratios. The variation of local Nusselt number has been shown with non-dimensional distance for different angles of attack and blockage ratios. The variation of average Nusselt number has also been shown with different angles of attack for blockage ratios. The local as well as average Nusselt number decreases as the height-ratio decreases for all non-dimensional distance and angle of attack, respectively, for rectangular prisms. The average Nusselt number for rectangular prisms of different blockage ratio varies with the angle of attack. But there is no definite angle of attack at different blockage ratio at which the value of average Nusselt number is either maximum or minimum. Empirical correlations for average Nusselt number have been presented for rectangular prism as a function of Reynolds number, Prandtl number and relevant non-dimensional parameters.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Heat and Mass Transfer - Volume 51, Issues 3–4, February 2008, Pages 736–746
نویسندگان
, ,