کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6703614 1428513 2018 56 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
3D Finite element modeling of circular reinforced concrete columns confined with FRP using a plasticity based formulation
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی عمران و سازه
پیش نمایش صفحه اول مقاله
3D Finite element modeling of circular reinforced concrete columns confined with FRP using a plasticity based formulation
چکیده انگلیسی
Strengthening reinforced concrete (RC) columns with external confining devices such as FRP wraps or steel tube is widely used in construction. By using external confining devices, both the strength and ductility of RC columns are significantly improved. However, numerical modeling to predict the capacity of strengthened RC columns is limited and often oversimplified. One of the biggest challenges in numerical modeling is to deal with unequal dilation between the concrete inner core (enclosed by both transverse steel and FRP wraps) and the concrete outer core (between the transverse steel and FRP wraps). Inaccurate modeling on the concrete dilatant behavior can lead to incorrect strength prediction. Sophisticated constitutive models which are able to model concrete dilation and robust modeling techniques are required. In this paper, three-dimensional non-linear finite element analysis (3D-NLFEA) of circular RC columns confined with conventional steel stirrups and FRP wraps is presented. In the FEA, the initial stiffness method with Process Modification (acceleration technique) is used to solve the equilibrium forces in the global solution. The constitutive model is based on the plasticity formulation proposed by the authors, which can capture the effective lateral modulus (EL) of the confining devices. This lateral modulus is obtained by observing the principal incremental stresses and strains at each element gauss point. It was found that, the lateral modulus is greatly affected by the boundary condition, dilatant behavior of the constitutive model and the Poisson's ratio of the external confining device. To validate the performance of the proposed model, several comparisons of the proposed model, using 3D-NLFEA, with experimental results is presented. The comparisons show that the predicted response using 3D-NLFEA and the experimental results of RC columns confined with FRP are in a good agreement.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Composite Structures - Volume 194, 15 June 2018, Pages 478-493
نویسندگان
, , ,