کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
742089 1462093 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous determination of propanil and monalide by modified glassy carbon electrode with nickel oxide nanoparticles, using partial least squares modified by orthogonal signal correction and wavelet packet transform
ترجمه فارسی عنوان
تعیین همزمان پروپان و مونالید با الکترود کربن شیشه ای کریستالی با نانوذرات اکسید نیک، با استفاده از حداقل مربعات جزئی، اصلاح شده با اصلاح سیگنال متعامد و تبدیل بسته های موجک
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• Modifying glassy carbon electrode by nickel oxide nanoparticles as a new sensor.
• Fabrication a new sensor for simultaneous determination of propanil, monalide.
• Simultaneous determination of propanil, monalide by differential pulse voltammetry.
• Using partial least squares, orthogonal signal correction, wavelet packet transform as a multivariate approach.
• Modified GCE has a low detection limit, high sensitivity, and long-term stability.

In this study a Glassy carbon electrode (GCE) modified with nickel oxide nanoparticles was developed. This electrode has a good sensitivity and electrocatalytic activity toward the oxidation of propanil and monalide over a wide concentration range. The propanil and monalide oxidation mechanism on the electrode surface was investigated, and the overall number of electrons involved in the electrocatalytic oxidation was found to be 3. The detection limit of this electrode for determination of propanil and monalide was 0.05 and 0.21 μM and its relative standard deviation for 10 independent measurements was 3 and 3.7%, respectively. Finally the proposed electrode exhibited several advantageous features, including simple preparation, fast response time, and good repeatability. The electrode was successfully applied for simultaneous determination of propanil and monalide based on partial least squares (PLS) regression with orthogonal signal correction (OSC) and wavelet packet transform (WPT) as pre-processing tools with overlapping peaks. In this case, by optimization, the kind of wavelet function, the decomposition level, the number of OSC components and number of PLS factors for the OSC-WPT-PLS method were selected as Daubechies 3, 1, 1 and 4, respectively. The relative standard errors (R.S.E) of prediction obtained for two components using OSC-WPT-PLS, WPT-PLS and PLS were compared. Experimental results demonstrated that the OSC-WPT-PLS method produced the best results among the three methods.

Modifying a glassy carbon electrode with nickel oxide nanoparticles for simultaneous determination of propanil and monalide in aqueous solution.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 197, 5 July 2014, Pages 326–333
نویسندگان
, , ,