کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
750856 1462083 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
High-performance field-effect transistor-type glucose biosensor based on nanohybrids of carboxylated polypyrrole nanotube wrapped graphene sheet transducer
ترجمه فارسی عنوان
ژنراتور بیوسنسور نوع گشتاور ترانزیستور با عملکرد بالا با استفاده از نانوکامپوزیت های نانولوله کربوکسیل شده پلیپیرلول
کلمات کلیدی
کاهش اکسید گرافین، نانولوله کربوکسیل-پلی پریرول، نانویبریدها، مزایده فیلد اثر، بی حس کننده ها
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی

We report a rapid-response and high-sensitivity field-effect transistor (FET)-based sensor with specificity towards glucose, based on reduced graphene oxide (rGO)-carboxylated polypyrrole (C-PPy) nanotube (NT) hybrids as the conductive channel. The rGO, C-PPy NTs, and rGO/C-PPy NT hybrids were characterized using Raman spectroscopy, Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). The results indicate that a well-organized structure was successfully prepared, based on specific interactions between the C-PPy NTs and the graphene sheets. Reliable electrical contacts were developed between the rGO/C-PPy NTs and the patterned-microelectrodes, which remained stable when exposed to the liquid-phase electrolyte. Liquid-ion-gated FETs composed of these rGO/C-PPy NT hybrids exhibited hole-transport behavior with higher conductivity than those of graphene sheets or C-PPy NTs because the C-PPy NTs formed a bridge between the graphene layers, resulting in effective electron transport. Glucose oxidase (GOx) was used as the capture probe, and was tightly combined with C-PPy NTs via a chemical coupling reaction, and glucose detection was performed via GOx, which catalyzes the oxidation of glucose in the rGO/C-PPy NTs hybrid FET biosensor. The FET biosensor provided a rapid response (< 1 s) with high sensitivity toward glucose with a limit of detection of 1 nM. This result is ca. 2–3 orders more sensitive than previous reported glucose sensor. The FET-type biosensor was highly reproducible and stable in air over a period of one month. Furthermore, the liquid-gated FET-type biosensor displayed specificity toward glucose in a mixed solution containing compounds found in biological fluids.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 208, 1 March 2015, Pages 532–537
نویسندگان
, , ,