کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7640783 1494855 2018 28 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Sequential coprecipitation and matrix removal for determination of cadmium impurities from multivitamin supplements by inductively coupled plasma mass spectrometry and method validation by isotope dilution analysis of SRM 3280 multivitamin/multielement ta
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Sequential coprecipitation and matrix removal for determination of cadmium impurities from multivitamin supplements by inductively coupled plasma mass spectrometry and method validation by isotope dilution analysis of SRM 3280 multivitamin/multielement ta
چکیده انگلیسی
In this paper, we examined three different sequential coprecipitation schemes based on Mg(OH)2 and CaF2 precipitation using triethylamine (TEA) and hydrofluoric acid (HF), respectively, for determination of cadmium (Cd) impurities from multivitamin/mineral (MVM) supplements by isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS). The schemes involved three-step coprecipitation with either TEA alone or in combination with HF and are designated as Scheme 1 (TEA-TEA-TEA), Scheme 2 (TEA-HF-TEA) and Scheme 3 (HF-TEA-TEA) according to the addition sequence of each reagent. Experiments were carried out with MVM solutions spiked with 60 μg L−1 Cd from a multielement standard solution. All schemes provided quantitative separation of Cd from MVM matrix. Scheme 1 was the least effective in removal of interfering concomitant elements, molybdenum (Mo) and tin (Sn). Scheme 2 performed better for Sn, but failed in eliminating Mo. Scheme 3 was the most effective in eliminating both Mo and Sn. Mo levels in test MVM solutions reduced from 4.3 μg mL−1 to as low as 0.014 μg mL−1 while that for Sn decreased from 0.5 μg mL−1 to 0.018 μg mL−1 allowing interference-free determination of Cd to be achieved. Salt-matrix due to Mg, Ca, P and K along with the essential elements (Mn, Fe, Cu and Zn) levels was also reduced significantly. Reagent blanks from HF and TEA were insignificant (0.008 μg L−1) allowing a limit of detection of 0.004 μg L−1 or 0.26 ng g−1 Cd to be achieved (3σ, n = 6). The performance of the coprecipitation method (Scheme 3) was validated by determination of Cd in multivitamin/multielement tablets certified reference material (SRM 3280) by ID-ICP-MS. Experimental results (ng g−1) and recoveries were 78.8 ± 4.7 (98.5%), 77.9 ± 5.2 (97.4%) and 76.5 ± 4.8 (95.6%) for 110Cd, 111Cd and 114Cd isotopes, respectively. Several commercial MVM supplements were analyzed using the method. Mean Cd concentration ranged from 21.4 ng g−1 to 93.3 ng g−1. These values are much lower than those reported to date for various MVM supplements by ICP-MS determinations without chemical separation.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microchemical Journal - Volume 139, June 2018, Pages 242-249
نویسندگان
, , , , , ,