Investigation of pitting corrosion of a copper tube in a heating system
چکیده انگلیسی

Electrochemical tests, as well as surface and chemical analyses were used to examine the mechanism of pitting failure of a copper tube. Synthetic tap water simulating the hot water in a heating system and field-used heating water at 60 °C were used as electrolytes in these tests. The results showed that the presence of a Cu(I) oxide layer on the copper surface is essential for pitting corrosion of a copper tube in hot synthetic tap water. Moreover, the pitting corrosion of copper tubes is preferred in heating water containing higher concentrations of Fe species and under stagnant condition.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Failure Analysis - Volume 17, Issue 6, September 2010, Pages 1424–1435