کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8209453 1532091 2015 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of a higher power cooling system for lithium targets
ترجمه فارسی عنوان
توسعه یک سیستم خنک کننده قدرت بالا برای اهداف لیتیوم
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
چکیده انگلیسی
The accelerator based Boron Neutron Capture Therapy beam at the University of Birmingham is based around a solid thick lithium target cooled by heavy water. Significant upgrades to Birmingham's Dynamitron accelerator are planned prior to commencing a clinical trial. These upgrades will result in an increase in maximum achievable beam current to at least 3 mA. Various upgrades to the target cooling system to cope with this increased power have been investigated. Tests of a phase change coolant known as “binary ice” have been carried out using an induction heater to provide a comparable power input to the Dynamitron beam. The experimental data shows no improvement over chilled water in the submerged jet system, with both systems exhibiting the same heat input to target temperature relation for a given flow rate. The relationship between the cooling circuit pumping rate and the target temperature in the submerged jet system has also been tested.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Radiation and Isotopes - Volume 106, December 2015, Pages 49-52
نویسندگان
, , , , ,