کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
867749 909792 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Site-specific sonoporation of human melanoma cells at the cellular level using high lateral-resolution ultrasonic micro-transducer arrays
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Site-specific sonoporation of human melanoma cells at the cellular level using high lateral-resolution ultrasonic micro-transducer arrays
چکیده انگلیسی

We developed a new instrumental method by which human melanoma cells (LU1205) are sonoporated via radiation pressures exerted by highly-confined ultrasonic waves produced by high lateral-resolution ultrasonic micro-transducer arrays (UMTAs). The method enables cellular-level site-specific sonoporation within the cell monolayer due to UMTAs and can be applicable in the delivery of drugs and gene products in cellular assays. In this method, cells are seeded on the biochip that employs UMTAs for high spatial resolution and specificity. UMTAs are driven by 30-MHz sinusoidal signals and the resulting radiation pressures induce sonoporation in the targeted cells. The sonoporation degree and the effective lateral resolution of UMTAs are determined by performing fluorescent microscopy and analysis of carboxylic-acid-derivatized CdSe/ZnS quantum dots passively transported into the cells. Models representing the transducer-generated ultrasound radiation pressure, the ultrasound-inflicted cell membrane wound, and the transmembrane transport through the wound are developed to determine the ultrasound-pressure-dependent wound size and enhanced cellular uptake of nanoparticles. Model-based calculations show that the effective wound size and cellular uptake of nanoparticles increase linearly with increasing ultrasound pressure (i.e., at applied radiation pressures of 0.21, 0.29, and 0.40 MPa, the ultrasound-induced initial effective wound radii are 150, 460, and 650 nm, respectively, and the post-sonoporation intracellular quantum-dot concentrations are 7.8, 22.8, and 29.9 nM, respectively) and the threshold pressure required to induce sonoporation in LU1205 cells is ∼0.12 MPa.


► We developed an instrumental method that employs high lateral–resolution ultrasonic micro–transducer arrays and enables cellular–level site–specific sonoporation within the cell monolayer.
► Novel biochip that employs micro–transducer arrays was created using microfabrication techniques.
► We investigated the degree and site–specificity of biochip–based sonoporation by performing fluorescent microscopy and analysis of sonoporation–enhanced cellular uptake of quantum dots.
► Above the threshold pressure, the cell membrane permeability and cellular uptake of nanoparticle increase linearly with increasing ultrasound pressure.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 27, Issue 1, 15 September 2011, Pages 25–33
نویسندگان
, , , , , , , , , , , , , ,