کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10140937 1646048 2019 22 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ultrasound-assisted solvent extraction of porous membrane packed solid samples: A new approach for extraction of target analytes from solid samples
ترجمه فارسی عنوان
استخراج حلال از طریق سونوگرافی از نمونه های جامد بسته بندی شده غشاء متخلخل: روشی جدید برای استخراج آنالیت های هدف از نمونه های جامد
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
For the first time, a porous membrane-based method is proposed for the extraction of target analytes directly from the solid samples. This method involves the packing of solid sample inside a porous polypropylene membrane sheet whose edges are heat-sealed to fabricate a bag. This bag is immersed in a suitable solvent and the analytes are extracted by the application of ultrasound energy. The various factors that affect the extraction performance such as extraction solvent, ultrasonication time, and ultrasound power are suitably optimized. The scope of this extraction method is very general, it can be used for the extraction of different classes of analytes from a variety of solid samples using suitable extraction solvents. The beauty of this method lies in the fact that only the small molecules such as analytes can pass through the membrane while the interfering or complex matrix species cannot pass through the membrane bag to the extraction solvent. Previously, the solid samples were first digested/dissolved into liquid medium and then analytes were extracted by membrane-protected adsorbents involving adsorption and desorption steps. With the proposed procedure, the steps of digestion/dissolution and the adsorption of analytes onto a suitable adsorbent are eliminated. Likewise, the steps of filtration and centrifugation are not required as the solid is effectively packed inside the membrane bag. Moreover, the extraction device is low cost, portable, easy to fabricate, and simple to use in the extraction process. In this work, proof of the concept is demonstrated by the extraction of polyaromatic hydrocarbons from the soil samples using GC-MS. This method provided reasonably low LODs ranging from 0.19 to 0.93 ng/mg. The intra-day accuracy and precision ranged from 87.5 to 109% and 0.8 to 5%, respectively while recoveries varied from 75.1 ± 4.9 to 106 ± 4.5%.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microchemical Journal - Volume 144, January 2019, Pages 117-123
نویسندگان
, , ,