کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
11276 729 2006 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cyclic flexure and laminar flow synergistically accelerate mesenchymal stem cell-mediated engineered tissue formation: Implications for engineered heart valve tissues
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی بیو مهندسی (مهندسی زیستی)
پیش نمایش صفحه اول مقاله
Cyclic flexure and laminar flow synergistically accelerate mesenchymal stem cell-mediated engineered tissue formation: Implications for engineered heart valve tissues
چکیده انگلیسی

Bone marrow-derived mesenchymal stem cells (BMSCs) are relatively accessible and exhibit a pluripotency suitable for cardiovascular applications such as tissue-engineered heart valves (TEHVs). Recently, Sutherland et al. [From stem cells to viable autologous semilunar heart valve. Circulation 2005; 111(21): 2783–91] demonstrated that BMSC-seeded TEHV can successfully function as pulmonary valve substitutes in juvenile sheep for at least 8 months. Toward determining appropriate mechanical stimuli for use in BMSC-seeded TEHV cultivation, we investigated the independent and coupled effects of two mechanical stimuli physiologically relevant to heart valves—cyclic flexure and laminar flow (i.e. fluid shear stress)—on BMSC-mediated tissue formation. BMSC isolated from juvenile sheep were expanded and seeded onto rectangular strips of nonwoven 50:50 blend poly(glycolic acid) (PGA) and poly(l-lactic acid) (PLLA) scaffolds. Following 4 days static culture, BMSC-seeded scaffolds were loaded into a novel flex-stretch-flow (FSF) bioreactor and incubated under static (n=12n=12), cyclic flexure (n=12n=12), laminar flow (avg. wall shear stress=1.1505 dyne/cm2; n=12n=12) and combined flex-flow (n=12n=12) conditions for 1 (n=6n=6) and 3 (n=6n=6) weeks. By 3 weeks, the flex-flow group exhibited dramatically accelerated tissue formation compared with all other groups, including a 75% higher collagen content of 844±278 μg/g wet weight (p<0.05p<0.05), and an effective stiffness (E) value of 948±233 kPa. Importantly, collagen and E values were not significantly different from values measured for vascular smooth muscle cell (SMC) -seeded scaffolds incubated under conditions of flexure alone [Engelmayr et al. The independent role of cyclic flexure in the early in vitro development of an engineered heart valve tissue. Biomaterials 2005; 26(2): 175–87], suggesting that BMSC-seeded TEHV can be optimized to yield results comparable to SMC-seeded TEHV. We thus demonstrated that cyclic flexure and laminar flow can synergistically accelerate BMSC-mediated tissue formation, providing a basis for the rational design of in vitro conditioning regimens for BMSC-seeded TEHV.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biomaterials - Volume 27, Issue 36, December 2006, Pages 6083–6095
نویسندگان
, , , ,