کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2650611 1563917 2016 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Keep pushing! Limiting interruptions to CPR; bag-valve mask versus i-gel® airway ventilation
ترجمه فارسی عنوان
نگه داشتن فشار! محدود کردن وقفه برای CPR؛ ماسک آمبوبگ در مقابل تهویه راه هوایی I-ژل
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پرستاری و مشاغل بهداشتی پرستاری
چکیده انگلیسی

BackgroundRecent recommendations made by ILCOR have de-emphasised the role of advanced airway management such as “endotracheal intubation” (ETI) during cardiac arrest in favour of maximising the number of chest compressions performed by rescuers. Maximising time available for compressions is achieved by minimising hands-off time (HOT). This has led to first responders and paramedics performing single rescuer CPR using a bag-valve-mask (BVM) device as opposed to the historical practice of intubating and ventilating via an endotracheal tube. Bag-valve-mask ventilations, especially during single rescuer CPR, are however associated with complications potentially resulting in increased ventilation times. More time spent on ventilations in the single rescuer scenario naturally leads to an increase in HOT and less time being available for compressions. It is postulated that the use of an appropriate supraglottic airway device (SAD) may decrease the time spent on the ventilation component of CPR and result in a decrease in HOT.ObjectivesThis pilot study evaluated how interruptions to chest compressions or hands-off time (HOT) are affected by the placement of an i-gel® airway vs. simple BVM ventilation during single rescuer CPR.Method16 participants performed two, ten-minute single rescuer CPR simulations, firstly using the BVM and later the i-gel® airway for ventilation. Data pertaining to ventilations and HOT in each scenario was statistically analysed and compared.ResultsThe i-gel® airway demonstrated a superior ease of ventilation compared to BVM alone and resulted in a reduction of time spent on ventilations overall. The i-gel® however took a mean of 29 s, ± 10 s, to secure which contributes considerably to HOT.ConclusionThe use of the i-gel® airway resulted in a considerable decrease in the amount of time spent on ventilations and in more compressions being performed. The overall reduction in HOT was, however, offset by the time it took to secure the device. Further investigation into the use and securing of the i-gel® airway in single rescuer CPR is recommended.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Health SA Gesondheid - Volume 21, December 2016, Pages 21–32
نویسندگان
, , ,