چکیده انگلیسی

The performance of mixture fraction models FDS4 and FDS5 is investigated under different global equivalence ratios (GER). Predictions of heat release rate (HRR), upper-layer temperature, and CO yield are compared with measurements considering their sensitivities to the lower limit of fuel, mixing time scale, and turbulence model constants. When using FDS4, the inclusion of an extinction model can result in significant variations in both total and volumetric HRR prediction. When using FDS5, the mixing model constant has significant effects on volumetric HRR prediction. At low GER (<0.23), the prediction of upper-layer temperature shows dependency on both the lower fuel limit and the mixing model constant, but the predicted temperature is always lower than measured temperature, with deviations in excess of 30%. At higher GER (0.53

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fire Safety Journal - Volume 45, Issue 5, August 2010, Pages 298–313