کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
443084 692537 2011 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An accurate, fast and robust method to generate patient-specific cubic Hermite meshes
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر گرافیک کامپیوتری و طراحی به کمک کامپیوتر
پیش نمایش صفحه اول مقاله
An accurate, fast and robust method to generate patient-specific cubic Hermite meshes
چکیده انگلیسی

In-silico continuum simulations of organ and tissue scale physiology often require a discretisation or mesh of the solution domain. Cubic Hermite meshes provide a smooth representation of anatomy that is well-suited for simulating large deformation mechanics. Models of organ mechanics and deformation have demonstrated significant potential for clinical application. However, the production of a personalised mesh from patient’s anatomy using medical images remains a major bottleneck in simulation workflows. To address this issue, we have developed an accurate, fast and automatic method for deriving patient-specific cubic Hermite meshes. The proposed solution customises a predefined template with a fast binary image registration step and a novel cubic Hermite mesh warping constructed using a variational technique. Image registration is used to retrieve the mapping field between the template mesh and the patient images. The variational warping technique then finds a smooth and accurate projection of this field into the basis functions of the mesh. Applying this methodology, cubic Hermite meshes are fitted to the binary description of shape with sub-voxel accuracy and within a few minutes, which is a significant advance over the existing state of the art methods. To demonstrate its clinical utility, a generic cubic Hermite heart biventricular model is personalised to the anatomy of four patients, and the resulting mechanical stability of these customised meshes is successfully demonstrated.

A schematic of the workflow described in the paper showing the sequential steps and feedback loops associated with the processing of patient data to produce a patient specific anatomical mesh.Figure optionsDownload high-quality image (132 K)Download as PowerPoint slideHighlights
► A step towards the clinical adoption of physiological simulations.
► A fast, robust and accurate method for the personalisation of cubic Hermite meshes.
► An accurate variational mesh warping technique for high order interpolation meshes.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Image Analysis - Volume 15, Issue 6, December 2011, Pages 801–813
نویسندگان
, , , , , , ,