کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
866988 1470984 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Graphene sheet-starch platform based on the groove recognition for the sensitive and highly selective determination of iodide in seafood samples
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Graphene sheet-starch platform based on the groove recognition for the sensitive and highly selective determination of iodide in seafood samples
چکیده انگلیسی


• The functionalization of graphene nanosheets was realized using a simple starch mixture procedure.
• The sensitivity and high selectivity for iodide determination was achieved based on the functionalization grapheme nanosheets.
• The groove recognition, a novel recognition model, was established to design and fabricate iodide-sensor.
• The idea for designing the sensor is expected to use in other biomolecule sensors.

The functionalization of graphene nanosheets was realized using a simple starch mixture to achieve a highly selective recognition of iodide, thereby surmounting the complicated reactions possibly leading to low yield during functionalization. The groove recognition for starch to iodide, a novel recognition model, was established. The starch-to-graphene nanosheet mass ratio of 3:2 produced an optimal current signal. The recognition and measurement procedures were conducted in different cells, respectively. These procedures improved the selectivity and sensitivity, and overcame the possibility of interference from coexisting ions. Under optimal conditions, the graphene sheet-starch electrode was immersed in a recognition cell at pH 2.0 for 10 min, afterward, in a measurement cell at pH 1.0 for quantitative analysis, resulting in the highest current signals obtained. The quantitative electrochemical measurements yielded a mean value of 214.6 mg/kg in actual samples of commercially available seafood sample, whereas the spectrophotometric measurements produced a mean value of 226.7 mg/kg. If the spectrophotometric value for the seafood sample is accurate, the percentage error for the electrochemical method is only 5.3%. Therefore, the electrochemical method is reliable for qualitative iodide measurements. The groove recognition was highlighted to elucidate the specific selectivity.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 47, 15 September 2013, Pages 396–401
نویسندگان
, , , , , , , ,