کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
11027729 1666161 2018 30 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Standardized X-ray tomography testing of additively manufactured parts: A round robin test
ترجمه فارسی عنوان
تست استاندارد توموگرافی اشعه ایکس از قطعات تولید شده به صورت اضافه شده: یک آزمایش رول روبین
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
چکیده انگلیسی
Micro computed tomography (microCT) allows non-destructive insights into the quality of additively manufactured parts and the processes that produce them. MicroCT has been used widely in this industry but the use of this technique is often time consuming and costly which reduces its potential impact and the benefits associated with its use. By using standardized test procedures, the analysis time and cost can be minimized and confidence in obtained results increased. A round robin test was conducted as follows: a series of standard test procedures (part sizes and shapes and test protocols) were applied - using one microCT system - to identical parts produced on a variety of metal additive manufacturing systems (specifically laser powder bed fusion systems). These are simple parts: a 10 mm cube, a 15 mm diameter vertical-built cylinder and a basic topology optimized example part - a bracket. The 15 mm diameter cylinder acts as witness specimen for the build of the complex part. All these were produced in Ti6Al4V, and in some cases parts were provided with variations in process parameters or manufacturing conditions which led to different types of intentional manufacturing flaws or defects. Various intentional and unintentional flaws were identified and quantified. The major result shown is that the analysis of a simple 10 mm cube clearly identifies incorrect process parameters even for very low levels of porosity, with unique porosity distributions and characteristics. It is found that generally this porosity extends to larger, more complex parts. The witness specimen (15 mm cylinder) allows clear identification of layered stop-start flaws, at a resolution better than a complex part built alongside it, allowing to identify defective builds. The results indicate a successful first step at standardized microCT analysis procedures for improvement of processes and quality control in additive manufacturing.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Additive Manufacturing - Volume 24, December 2018, Pages 125-136
نویسندگان
, ,