کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
10122784 | 1642855 | 2018 | 69 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Performance of double effect H2O-LiCl absorption refrigeration systems and comparison with H2O-LiBr systems, Part 1: Energy analysis
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Performance of double effect H2O-LiCl absorption refrigeration systems and comparison with H2O-LiBr systems, Part 1: Energy analysis Performance of double effect H2O-LiCl absorption refrigeration systems and comparison with H2O-LiBr systems, Part 1: Energy analysis](/preview/png/10122784.png)
چکیده انگلیسی
In this study, the series, parallel and reverse parallel configurations of double effect H2O-LiCl vapour absorption refrigeration system (VARS) are thermodynamically modeled to provide performance comparison among the three systems under identical operating conditions. Parametric analysis is performed to investigate the effect of component temperatures and distribution ratio on coefficient of performance (COP) of the double effect VARS configurations. Results show that the maximum solution concentration, which is limited to 0.5 in H2O-LiCl VARS, is mainly controlled by the system operating temperatures. In case of the parallel and reverse parallel systems, maximum solution concentration also depends upon the distribution ratio. It was found that there exists an optimal combination of HPG and low pressure generator (LPG) temperature at which the COP of a particular double effect H2O-LiCl system is maximized. This optimal combination however varies with temperatures in the other components (absorber, condenser and evaporator). A performance comparison between double effect H2O-LiCl and H2O-LiBr systems under identical conditions showed better performance in case of the double effect H2O-LiCl VARS configurations. Due to its low maximum concentration limit (0.5 against 0.65 of H2O-LiBr VARS), double effect H2O-LiCl VARS configurations would be more appropriate and efficient compared to the H2O-LiBr systems, particularly at low LPG and HPG temperature applications.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Thermal Science and Engineering Progress - Volume 8, December 2018, Pages 184-203
Journal: Thermal Science and Engineering Progress - Volume 8, December 2018, Pages 184-203
نویسندگان
D. Konwar, T.K. Gogoi,