کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10286072 504142 2005 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Monitoring the energy-use effects of cool roofs on California commercial buildings
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Monitoring the energy-use effects of cool roofs on California commercial buildings
چکیده انگلیسی
Using the measured data and calibrated simulations, we estimated savings for similar buildings installing cool roofs in retrofit applications for all 16 California climate zones. For similar retail stores in climate zones 2 and 4-16, installing a cool roof can save about 6-15 kWh/m2/year of conditioned area. In climate zones 2-16, estimates of average peak demand savings for hours noon-5 p.m. range from 2.9 to 5.8 W/m2. For similar school buildings in climate zones 2-16, installing a cool roof can save from 3 to 6 kWh/m2/year of conditioned roof area. For all 16 climate zones estimates of average peak demand savings for hours noon-5 p.m. range from 2.6 to 3.8 W/m2. In similar cold storage buildings in all 16 climate zones, installing a cool roof can save about 4.5-7.4 kWh/m2/year of conditioned roof area. In all 16 climate zones, estimates of average peak demand savings for hours noon-5 p.m. range from 3.9 to 6.6 W/m2.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 37, Issue 10, October 2005, Pages 1007-1016
نویسندگان
, , ,