کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10534236 961909 2005 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Mass spectrometric analysis of affinity-captured proteins on a dendrimer-based immunosensing surface: investigation of on-chip proteolytic digestion
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Mass spectrometric analysis of affinity-captured proteins on a dendrimer-based immunosensing surface: investigation of on-chip proteolytic digestion
چکیده انگلیسی
The monolayer of fourth-generation poly(amidoamine) dendrimers was adopted to construct the immunoaffinity surface of an antibody layer. The antibody layer as a bait on the dendrimer monolayer was found to result in high binding capacity of antigenic proteins and a reliable detection. The affinity-captured protein at the immunosensing surface was subjected to direct on-chip tryptic digestion, and the resulting proteolytic peptides were analyzed by using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. The performance of the on-chip digestion procedure was investigated with respect to the ratio of trypsin to protein, digestion time, composition of a reaction buffer, and the amount of affinity-captured protein on a surface. Addition of a water-miscible organic solvent to a reaction buffer had no significant effect on the digestion efficiency under the optimized digestion conditions. The on-chip digestion method identified the affinity-captured bovine serum albumin (BSA), lysozyme, and ferritin at the level of around 100 fmol. Interestingly, the detected number of peptide hits through the on-chip digestion was almost similar regardless of the amount of captured protein ranging from low- to high-femtomole levels, whereas the efficiency of in-solution digestion decreased significantly as the amount of protein decreased to low-femtomole levels. The structural alignment of the peptide fragments from on-chip-digested BSA revealed that the limited exterior of the captured protein is subjected to attack by trypsin. The established detection procedures enabled the identification of BSA in the biological mixtures at the level of 0.1 ng/mL. The use of antibodies against the proteins involved in the metabolic pathway of l-threonine in Escherichia coli also led to discrimination of the respective target proteins from cell lysates.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytical Biochemistry - Volume 337, Issue 2, 15 February 2005, Pages 294-307
نویسندگان
, , , , , , , ,