کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1193195 1492301 2012 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
High precision tungsten isotope measurement by thermal ionization mass spectrometry
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
High precision tungsten isotope measurement by thermal ionization mass spectrometry
چکیده انگلیسی

We describe a new technique for measuring the isotopic abundance of 182W with improved precision in natural silicate samples. After chemical purification of W through a four-step ion exchange chromatographic separation, the W isotopic composition is measured as WO3− by negative thermal ionization mass spectrometry using a Thermo-Fisher Triton instrument. Amplifier biases are cancelled by using amplifier rotation, and Faraday cup biases are monitored by using a cup configuration that allows two-line data acquisition. Data are initially corrected for oxide interferences, assuming a predefined O isotope composition, and for mass fractionation, by normalization to 186W/184W or 186W/183W, using an exponential law. Despite these corrections, isotopic ratios exhibit small but strongly correlated variations. This second-order effect may reflect a mass dependent change of O isotope composition in the measured W (and Re) oxides, and is corrected by normalization to 183W/184W using a linear law. Repeated analysis of an Alfa Aesar W standard (n = 39), and of three dissolutions of a La Palma (Canary Islands) basalt, applying the double normalization procedure, demonstrate external reproducibility of 182W/184W within ±4.5 ppm (2σ SD). Repeated measurement of a gravimetrically prepared mixture of a natural W standard and a 182W enriched spike shows that differences in 182W/184W of ∼10 ppm can be well resolved using this method. The external reproducibility of ±4.5 ppm is ∼5 times more precise than conventional W isotope measurements by MC-ICP-MS. The new technique constitutes an ideal tool for investigating the W isotope composition of terrestrial rocks for potential contributions from the core, and late accreted extraterrestrial materials.

Figure optionsDownload high-quality image (40 K)Download as PowerPoint slideHighlights
► We present a new high precision 182W/184W measurement protocol by N-TIMS.
► Instrumental mass fractionation requires correction using a double normalization procedure.
► This procedure allows correction of isotope fractionation for both, tungsten and oxygen.
► This method permits an external reproducibility of <5 ppm for natural samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Mass Spectrometry - Volume 309, 1 January 2012, Pages 109–117
نویسندگان
, ,