کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1227766 1494872 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Optimization of a methodology for sampling of five polycyclic aromatic hydrocarbons in saline waters using a semipermeable membrane device
ترجمه فارسی عنوان
بهینه سازی روش برای نمونه برداری از پنج هیدروکربن های آروماتیک چند حلقه ای در آب شور با استفاده از دستگاه غشایی نیمه رسانا
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A sampling device was developed for sampling PAH from saline waters.
• Acetonitrile was tested as collection phase inside the semipermeable membrane device.
• The PAH were determined in the extracts by HPLC with UV detection.
• Five PAH were tested and benzo(k)fluoranthene presented the lowest transference percentage.

Aquatic pollution by organic compounds, many of which are toxic and carcinogenic, has aroused great concern. Polycyclic aromatic hydrocarbons (PAH) are pollutants that stand out due to their carcinogenicity and potential risk to human health. The goal of the present study was to evaluate the application of semipermeable membrane devices (SPMD), consisting of low-density polyethylene filled with acetonitrile, for the sampling of some PAH (naphthalene, anthracene, fluoranthene, pyrene and benzo(k)fluoranthene) in aqueous media. Optimization of the sampling methodology in terms of exposition time and volume of the phases (water sample and internal solvent) was performed. Also, the verification of the influence of some factors that could interfere in the sampling, such as ionic strength and temperature, was carried out. The results obtained in the present work demonstrated that an 8 cm membrane segment, filled with 3 mL acetonitrile, was able to extract the five analytes from aqueous medium. The extraction efficiency depended on the size of the substance, being observed higher extraction for the compounds with lower mass. Two saline water samples were analyzed, and recovery tests were performed to evaluate the calibration strategy. Calibration with a synthetic saline water with 50‰ salinity provided good recovery percentages (82–119%) for naphthalene, anthracene and fluoranthene, whereas for pyrene and benzo(k)fluoranthene, analyte addition approach must be employed. Also, naphthalene could be identified in a third sample of highly saline production water, indicating that the proposed sampling device can be employed for screening purposes.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microchemical Journal - Volume 122, September 2015, Pages 96–101
نویسندگان
, , , ,