Determination of mercury in size fractionated road dust samples by flow injection-cold vapor-atomic absorption spectrometry
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of mercury in size fractionated road dust samples by flow injection-cold vapor-atomic absorption spectrometry
چکیده انگلیسی

An investigation was carried out to explore the effect of citric, hydrochloric, oxalic and tartaric acids on mercury vapor generation in a flow injection system in conjunction with atomic absorption spectrometry detection (CV-AAS) for its determination in road dust samples. Samples were collected in Buenos Aires (Argentina) during two months at 15 sites grouped in five zones with different urban characteristics and traffic profile. They were sieved in four fractions (with the following particle diameter (d): A: d < 37 μm, B: 37 < d < 50 μm, C: 50 < d < 75 μm, and D: 75 < d < 100 μm) before Hg determination. The operating conditions (chemical and physical parameters) and the type and concentration of the acids studied (citric, hydrochloric, oxalic and tartaric) were assessed for the efficient generation of Hg. The interfering effect of metals and metalloids, present as minor and major concentrations in road dust, on Hg signal were evaluated using the four acids. Hydrochloric acid resulted to be the most convenient reaction medium in terms of sensitivity but a suitable control of interferences was not reached. For a complex matrix such as road dust, the best control of interferences was achieved when oxalic acid was tested, even when lower Hg signal was obtained in comparison with HCl. The detection limit (3σ criterion) turned out to be 0.3 ng g− 1. For checking accuracy, two certified reference materials were analyzed and results were in good agreement with certified values. Mercury concentrations in road dust ranged between 0.1 μg g− 1 and 4.6 μg g− 1 and the mean concentration value resulted to be 1.09 μg g− 1. In the four fractions, Hg concentrations (μg g− 1) varied as follows: Fraction A (< 0.0003–3.51); Fraction B (0.49–4.63); Fraction C (0.20–1.36) and Fraction D (0.16–1.88). The procedure is simple, rapid and robust.


► We determined by the first time Hg on road dust samples collected in Buenos Aires.
► We compared four acid media for Hg vapor generation.
► The effect of each acid media on the control of interferences was assessed.
► The use of organic acids for Hg vapor generation is the most correct procedure from the environmental point of view.
► This work reports by the first time concentrations of Hg in Buenos Aires road dust as well as information on its origin.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microchemical Journal - Volume 105, November 2012, Pages 77–82