کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1228613 | 968486 | 2006 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Feasibility of employing permanent chemical modifiers for the determination of cadmium in coal using slurry sampling electrothermal atomic absorption spectrometry
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
Iridium and ruthenium, alone and in combination with tungsten, thermally deposited on the platform of a transversely heated graphite tube, were investigated for their suitability as permanent chemical modifiers for the determination of cadmium in coal slurries by electrothermal atomic absorption spectrometry (ET AAS). The conventional mixed palladium and magnesium nitrates (Pd-Mg) modifiers, added in solution, were also investigated for comparison. The latter one showed the best performance for aqueous solutions, and the mixed W-Ir and W-Ru permanent modifiers had the lowest stabilizing power. All of the investigated modifiers lost some of their stabilizing power when coal slurries were investigated. The Pd-Mg modifier, pure Ir and Ru, and a mixture of 300 μg W + 200 μg Ir could stabilize Cd at least to a pyrolysis temperature of 600 °C, whereas all the other combinations already failed at temperatures above 500-550 °C. Additional investigations of the supernatant liquid of the slurries supported the assumption that the high acid concentration of the slurries and/or a concomitant leaching out of the coal might be responsible for the reduced stabilizing power of the modifiers. The maximum applicable pyrolysis temperature of 600 °C was not sufficient to reduce the background absorption to a manageable level in the majority of the coal samples. High-resolution continuum source ET AAS revealed that the continuous background absorption was exceeding values of A = 2, and was overlapping with the analyte signal. Although the latter technique could correct for this background absorption, some analyte was apparently lost with the rapidly vaporizing matrix so that the method could not be considered to be rugged. A characteristic mass of 1.0 pg and a detection limit of 0.6 ng gâ 1 could be obtained under these conditions.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microchemical Journal - Volume 82, Issue 2, April 2006, Pages 174-182
Journal: Microchemical Journal - Volume 82, Issue 2, April 2006, Pages 174-182
نویسندگان
Liane Bianchin, Daniela Nadvorny, Alessandra Furtado da Silva, Maria Goreti Rodrigues Vale, Márcia Messias da Silva, Walter N.L. dos Santos, Sergio L.C. Ferreira, Bernhard Welz, Uwe Heitmann,