کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1266149 1496883 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cavitation distribution within large phantom vessel and mechanical damage formed on surrounding vessel wall
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Cavitation distribution within large phantom vessel and mechanical damage formed on surrounding vessel wall
چکیده انگلیسی


• Cylindrical hole is formed opposite the wave propagation direction.
• Cylindrical hole is formed where bubbles gather and bright SL is emitted.
• The focus location have big influence on SL distribution and mechanical damage.
• UCAs presence is essential for SL observation and mechanical damage formation.

Blood vessel is one of the most important targets encountered during focused ultrasound (FU) therapy. The lasting high temperature caused by continuous FU can result in structural modification of small vessel. For the vessel with a diameter larger than 2 mm, convective cooling can significantly weaken the thermal effect of FU. Meanwhile, the continued presence of ultrasound will cause repetitive cavitation and acoustic microstreaming, making comprehension of continuous wave induced cavitation effect in large vessels necessary. The Sonoluminescence (SL) method, mechanical damage observation and high-speed camera were used in this study to investigate the combination effect of ultrasound contrast agents (UCAs) and continuous FU in large phantom vessels with a diameter of 10 mm without consideration of thermal effect. When the focus was positioned at the proximal wall, cylindrical hole along the acoustic axis opposite the ultrasound wave propagation direction was observed at the input power equal to or greater than 50 W. When the focus was located at the distal wall, only small tunnels can be found. The place where the cylindrical hole formed was corresponding to where bubbles gathered and emitted brilliant light near the wall. Without UCAs neither such bright SL nor cylindrical hole can be found. However, the UCAs concentration had little influence on the SL distribution and the length of cylindrical hole. The SL intensity near the proximal vessel wall and the length of the cylindrical hole both increased with the input power. It is suggested that these findings need to be considered in the large vessel therapy and UCAs usage.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasonics Sonochemistry - Volume 20, Issue 6, November 2013, Pages 1376–1383
نویسندگان
, , , ,