کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1394110 1501136 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Enantiopure bifunctional chelators for copper radiopharmaceuticals – Does chirality matter in radiotracer design?
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آلی
پیش نمایش صفحه اول مقاله
Enantiopure bifunctional chelators for copper radiopharmaceuticals – Does chirality matter in radiotracer design?
چکیده انگلیسی


• Enantiopure bifunctional chelators (BFCs) were designed for radiopharmaceuticals.
• The chirality effect of BFCs was evaluated on integrin αvβ3 targeted agents.
• Negligible effect of BFC chirality was observed by in vitro and in vivo evaluations.
• BFC chirality may play a role in other receptor targeted radiopharmaceuticals.

It is well recognized that carbon chirality plays a critical role in the design of drug molecules. However, very little information is available regarding the effect of stereoisomerism of macrocyclic bifunctional chelators (BFC) on biological behaviors of the corresponding radiopharmaceuticals. To evaluate such effects, three enantiopure stereoisomers of a copper radiopharmaceutical BFC bearing two chiral carbon atoms were synthesized in forms of R,R-, S,S-, and R,S-. Their corresponding peptide conjugates were prepared by coupling with a model peptide sequence, c(RGDyK), which targets the αvβ3 integrin for in vitro and in vivo evaluation of their biological behaviors as compared to the racemic conjugate. Despite the chirality differences, all the conjugates showed a similar in vitro binding affinity profile to the αvβ3 integrin (106, 108, 85 and 100 nM for rac-H2-1, RR-H2-1, SS-H2-1, and RS-H2-1 respectively with all p values > 0.05) and a similar level of in vivo tumor uptake (2.72 ± 0.45, 2.60 ± 0.52, 2.45 ± 0.48 and 2.88 ± 0.59 for rac-64Cu-1, RR-64Cu-1, SS-64Cu-1, and RS-64Cu-1 at 1 h p.i. respectively). Furthermore, they demonstrated a nearly identical biodistribution pattern in major organs (e.g. 2.07 ± 0.21, 2.13 ± 0.58, 1.70 ± 0.20 and 1.90 ± 0.46 %ID/g at 24 h p.i. in liver for rac-64Cu-1, RR-64Cu-1, SS-64Cu-1, and RS-64Cu-1 respectively; 1.80 ± 0.46, 2.30 ± 1.49, 1.73 ± 0.31 and 2.23 ± 0.71 at 24 h p.i. in kidneys for rac-64Cu-1, RR-64Cu-1, SS-64Cu-1, and RS-64Cu-1 respectively). Therefore we conclude that the chirality of BFC plays a negligible role in αvβ3-targeted copper radiopharmaceuticals. However, we believe it is still worthwhile to consider the chirality effects of BFCs on other targeted imaging or therapeutic agents.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Medicinal Chemistry - Volume 80, 10 June 2014, Pages 308–315
نویسندگان
, , , , , ,