کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
143938 | 438916 | 2016 | 8 صفحه PDF | دانلود رایگان |
• Systematic experiments were carried out to investigate ash accumulation in flue gas.
• Engineering acid dew temperature (EADT) is a key parameter in ash accumulation.
• Particles accumulate substantially when gas temperature is 20–40 °C below EADT.
• H2O and SO3 contents and dust concentration also affect ash accumulation.
Accumulation of small particles is beneficial for dust removal. We have carried out experiments to investigate the influences of flue gas properties, especially temperature, humidity, sulfuric acid, and dust concentrations, on ash particle accumulation. The ash used was collected from an electric precipitator of a coal-fired power station. It is found that ash accumulation is strongly influenced by the flue gas temperature in comparison with the Engineering Acid Dew Temperature (EADT). With decreasing temperature below the EADT, both the sulfuric acid in flue gas and the ash humidity rise, and the collected particles weight and sizes increase. Therefore, the flue gas temperature can be controlled to enhance particle accumulation and improve ash collection efficiency.
Figure optionsDownload as PowerPoint slide
Journal: Advanced Powder Technology - Volume 27, Issue 4, July 2016, Pages 1473–1480