A theoretical study was performed to investigate the punching shear strength of interior slab–column connections made of steel fiber reinforced concrete (FRC). In the steel FRC slab–column connection, the shear force applied to the critical section is resisted by both the compression zone and the tension zone at the critical section. The shear capacity of the compression zone was defined by considering the interaction between the shear and the normal stresses developed at the critical section. The shear capacity of the tension zone was defined by considering the post-cracking tensile strength of FRC. By using the shear capacity, a new strength model for the punching shear strength of steel FRC slab–column connections was developed. The proposed strength model was verified using existing test results and showed very good accuracy. For convenience in design, a simplified design equation was also developed.
Journal: Cement and Concrete Composites - Volume 29, Issue 5, May 2007, Pages 409–420