کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1510618 1511165 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An Experimental Investigation of a Novel Trombe Wall with Venetian Blind Structure
ترجمه فارسی عنوان
بررسی تجربی یک دیوار ترومای رمان با ساختار نابینا ونیزی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
چکیده انگلیسی

A novel Trombe wall façade with DC fan integrated on the venetian blind structure is presented in this paper. To study the thermal performance of it, a series of comparative experiments have been conducted in winter and summer respectively in Hefei.In winter the experiment has been carried out (close assisted DC fan) at the varying of the slat angles (θ=0°, 45°, 90°) between the comparable two rooms, the results show that according to the measured weather data the value of normalized temperature rise is larger when the blind slat angle is set at 45°, which means the optimal effect of heat accumulation. In summer, to minimize the effect of undesired heat gains and enhance air vent velocity, the system focuses the blind slat angle at 90°(with reference to horizontal) and opens the assisted fan,then comparisons are made among the air temperature of the two rooms at 22 °C,24 °C and 26 °C and it indicates that the average temperature difference of the south wall between the two rooms is 1.95 °C,1.72 °C, 1.71 °C respectively and the maximum heat gain difference is reach up to 3.66×103KJ within 8 hours(8:00-16:00). The results reveal that a promising technicof trombe wall structure integrated venetian-type collector and it could operate high efficiently.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy Procedia - Volume 70, May 2015, Pages 691-698