کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1510915 1511180 2014 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Increased Reliability for J0-analysis by QSSPC
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
Increased Reliability for J0-analysis by QSSPC
چکیده انگلیسی

This work investigates the influence of physical parameters and of different methods on the analysis of QSSPC measurements with the aim to extract J0-values of diffused surfaces. We show that the right choice of not only the parameter-set and physical models but also the method is crucial. The comparison with injection dependent simulation data leads to a deviation of up to 34 % from the absolute J0-value for parameters found in literature. In contrast, the recently implemented method in the WCT-120 lifetime tester software [1] which accounts for band-gap narrowing in the substrate agrees within 3 % over the full range of assumed base doping. Furthermore we show that the carrier-lifetime in the substrate shows a significant influence on J0-values obtained using the absolute measured recombination and leads to overestimation of up to 50 % even for high base-lifetimes of τSRH = 1 ms. The implemented parameter-set and analysis method is based on common accepted models and consistent with various simulation tools, and thus allows for the extraction and comparison of injection- and substrate-independent J0-values.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy Procedia - Volume 55, 2014, Pages 101-106